RAID (Redundant Array of Independent Disks) is a data storage technology that combines multiple disk drive components into a logical unit. RAID offers fault tolerance and improves performance by distributing data across multiple drives. There are several levels or modes of RAID that provide different combinations of performance, redundancy, and disk capacity utilization.

Quick overview of RAID levels

The most common RAID levels are:

  • RAID 0 – Stripe sets without parity or mirroring. High performance but no redundancy.
  • RAID 1 – Mirroring without parity or striping. Redundancy without fault tolerance.
  • RAID 5 – Striping with distributed parity. Redundancy with fault tolerance.
  • RAID 6 – Striping with double distributed parity. High redundancy but slow write performance.
  • RAID 10 – Striping and mirroring without parity. Medium redundancy, high performance.

What is RAID 0?

RAID 0, also known as disk striping, is a performance-focused RAID mode that doesn’t offer any redundancy. It splits data evenly across two or more disks without parity information. Since there is no duplication of data or parity calculations, RAID 0 provides fast reads and writes and maximizes disk capacity. However, it offers no protection against disk failure – if one disk fails, all data across the RAID 0 array will be lost.

RAID 0 is best suited for non-critical data where high speed is desired. For example, it can improve performance for gaming PCs or video editing workstations that need to read/write large files quickly. The tradeoff is increased risk of data loss if a drive fails.

Advantages of RAID 0

  • Increased disk read/write performance – data is split amongst disks for faster IO.
  • Full capacity utilization – no capacity lost to redundancy like mirroring or parity.

Disadvantages of RAID 0

  • No fault tolerance – complete data loss if any disk fails.
  • Less secure since all data is lost with a disk failure.

What is RAID 1?

RAID 1, also known as disk mirroring, involves duplicating data across two or more disks. It provides redundancy by maintaining multiple identical copies of data, but does not use parity or striping techniques. Any write operation is performed to all disks simultaneously, while read operations can be performed in parallel to increase performance.

RAID 1 safeguards against loss of data due to disk failure. If one disk fails, the mirrored copy on another disk can still be accessed. However, it requires at least two disks with capacity equivalent to the largest drive. So 50% of total capacity is used for redundancy purposes.

RAID 1 is suited for mission critical data that needs full redundancy. For example, ecommerce or banking transactions, medical records, or other sensitive files that cannot have any downtime or potential for data loss.

Advantages of RAID 1

  • Full data redundancy – complete backup via mirroring.
  • High read performance – reads can be parallelized across disks.
  • Write performance better than parity-based RAID.

Disadvantages of RAID 1

  • 50% redundancy overhead – requires at least 2x total disk capacity.
  • No fault tolerance – data still lost if both disks in a mirror fail.
  • Lower capacity utilization than RAID 0 or 5.

What is RAID 5?

RAID 5 stripes data and parity information across 3 or more disks. The parity allows the array to recover data if any single disk fails. Upon failure, the missing portion can be calculated from the remaining data and parity blocks. RAID 5 requires at least 3 disks to implement.

RAID 5 provides fault tolerance along with good read performance and capacity utilization. Writes are slower than other levels due to parity calculation on each write. RAID 5 is a popular choice for storage that requires redundancy without the 50% overhead of mirroring.

It works well for medium sized servers, NAS devices, or small business storage where some redundancy is critical but large mirrors are cost prohibitive. Most RAID 5 implementations use HDDs due to the sequential write patterns of parity data.

Advantages of RAID 5

  • Good redundancy – can survive a single drive failure.
  • Increased read performance via striping.
  • Efficient capacity utilization compared to RAID 1 mirroring.

Disadvantages of RAID 5

  • Slower write performance due to parity calculations.
  • HDD preferred over SSD due to write amplification on SSDs.
  • RAID rebuild times can be significant for large arrays.

What is RAID 6?

RAID 6 provides redundancy by using double distributed parity. Data is striped across disks like RAID 5, but it uses two separate parity blocks per stripe. This allows the array to survive the loss of up to two disks. RAID 6 requires a minimum of 4 disks.

The double parity provides excellent fault tolerance and redundancy. RAID 6 can withstand up to two disk failures with no data loss. However, the dual parity calculations significantly reduce write performance. RAID 6 is mainly used for mission critical data that requires high redundancy and cannot have any downtime.

For example, RAID 6 sees heavy use in enterprise and cloud storage systems where maximum data integrity is essential. The performance drawbacks are mitigated by using high speed enterprise SSDs and controllers.

Advantages of RAID 6

  • Excellent fault tolerance – survives up to 2 disk failures.
  • Great for mission critical data that requires high redundancy.

Disadvantages of RAID 6

  • Slow write speeds due to dual parity calculation.
  • Minimum 4 disks required which increases cost.
  • Not ideal for typical desktop or consumer use.

What is RAID 10?

RAID 10 combines both mirroring and striping for redundancy and performance. It creates a striped set from mirrored disk pairs, for example with 4 disks: 1&2 and 3&4 are each mirrors, then 1&2 is striped with 3&4.

This provides the redundancy of RAID 1 with the performance advantages of RAID 0 striping. RAID 10 can survive any single disk failure, and usually provides faster writes than parity-based RAID levels.

At least 4 disks are required for a minimal RAID 10 array. It is well suited for applications that demand both high performance and good fault tolerance like databases, virtualization, and high traffic servers.

Advantages of RAID 10

  • Combines redundancy and performance.
  • Survives up to 1 disk failure in each mirror.
  • Very fast read/write speeds from striping.

Disadvantages of RAID 10

  • 50% redundancy overhead like RAID 1 mirroring.
  • Requires minimum 4 disks.
  • More expensive than single parity (RAID 5) redundancy.

RAID Level Comparison

Here is a summary comparing the different RAID levels:

RAID Level Minimum Disks Redundancy Performance Capacity Utilization
RAID 0 2 None Excellent 100%
RAID 1 2 Full redundancy Excellent read, Slow write 50%
RAID 5 3 Single disk fault tolerance Good read, Slow write 67% to 94%
RAID 6 4 Double disk fault tolerance Slow 50% to 88%
RAID 10 4 Up to 1 disk per mirror Excellent 50%

Choosing the right RAID level

There are several factors to consider when choosing a RAID level:

  • Required redundancy – How much fault tolerance and redundancy is needed? For non-critical data RAID 0 would suffice. For highly critical data, RAID 6 provides the most redundancy.
  • Performance needs – RAID 0 and 10 provide the best overall performance. RAID 1 has excellent read speeds, but slower writes.
  • Available disks – The number of disks available may dictate which RAID levels can be implemented. RAID 10 requires a minimum of 4 disks, for example.
  • Cost – RAID 6 provides excellent redundancy but requires more disks. RAID 10 delivers great performance and redundancy but with 50% overhead.
  • Drive types – Some RAID levels work better with HDDs or SSDs. RAID 5 is optimal for HDDs while RAID 10 handles SSDs well.

In summary:

  • RAID 0 – Performance, no redundancy
  • RAID 1 – Redundancy without fault tolerance
  • RAID 5 – Redundancy with single disk fault tolerance
  • RAID 6 – High redundancy, slow writes
  • RAID 10 – Redundancy and performance

The RAID level choice depends on the specific storage needs and budget when designing a RAID array.

RAID Controller Implementation

RAID can be implemented in hardware or software:

  • Hardware RAID – Uses a dedicated RAID controller card with onboard storage processors. Handles all RAID calculations and distribution.
  • Software RAID – RAID management is handled by the operating system and drivers. Uses the system CPU for RAID computations.

Hardware RAID provides better performance since it offloads the RAID tasks from the main CPU. However, software RAID costs less since a RAID card is not needed. Many motherboards include software RAID support.

For enterprise and mission critical use, hardware RAID is strongly recommended. The dedicated RAID processors and battery-backed write caching enable excellent performance and data protection. High end NAS devices also typically use hardware RAID.

Software RAID can be suitable for home builds or non-critical use where cost savings outweighs the performance benefits of hardware RAID.

RAID Management and Monitoring

Managing and monitoring a RAID helps ensure its health and optimum performance:

  • Most RAID controllers include management utilities to view RAID status, disk health, volume capacity, etc.
  • Monitoring read/write speeds can identify performance issues or slow disks.
  • Tools like S.M.A.R.T provide disk health stats and predictive failure alerts.
  • Watching for recoverable and unrecoverable errors indicates reliability problems.
  • Most RAIDs support email/text alerts for critical events like failure or a degraded array.
  • Temperature monitoring since overheating can lead to disk failure.

A well maintained RAID should provide years of high performance and reliable data redundancy. Ignoring RAID health and errors can lead to catastrophic failure and unrecoverable data loss.

Conclusion

RAID combines multiple storage drives for performance and redundancy. Choosing the optimal RAID level depends on cost, performance, and redundancy needs. RAID 0 maximizes speed at the cost of no redundancy. RAID 1 mirrors drives for redundancy. RAID 5 provides single-disk fault tolerance via parity. For mission critical data, RAID 6 offers excellent redundancy while RAID 10 balances redundancy and speed.

Hardware RAID controllers provide the best performance and management capabilities but cost more than software RAID. Monitoring RAID health stats, disk errors, and temperature helps avoid failures.

RAID provides flexible data redundancy and improves storage performance. Matching the proper RAID level to the storage requirements results in an optimal balance of speed, reliability and efficient use of disk capacity.